Home > TriStar® Screw Kit > Screws

Screws for Bone Grafting

Get screws designed to secure membranes and TriStar titanium meshes to assist with oral bone grafting. These adjustable tenting screws have a tapered and threaded design, and are available in a variety of sizes, ranging from 3–14mm. They allow the clinician to adjust the height and direction when used in tenting procedures. Additional longer fully threaded screws are available in lengths of 15mm, 18mm, 21mm, and 24mm for vertical vascular osteotomy procedures. All of our screws have received a patent in 2021.

Competitor tenting screws have an interrupted shelf in between the threaded and unthreaded portions, which locks in the height of the tenting portion of the screw. Our tapered design allows the clinician to adjust the height of the “tent pole” to suit the clinical application. This square lock connection offers an ultra-secure fit that reduces driver slippage and provides excellent driving torque. Best of all, with this patented design, all these benefits can be achieved with a single tool.
Sort By:
Page of 1
5mm: Fully Threaded (Pack of 5) 5mm: Fully Threaded (Pack of 5)

  • The 5mm TriStar screw is fully threaded and designed to be used to secure membranes and the TriStar titanium mesh. The TriStarscrews are sold in packs of 5.
  • Each screw in the TriStarBone Graft Fixation System is self-drilling and does not require the clinician to pre-drill a hole in the host.
  • Each screw also features the Impladent Ltd. tapered SquareLock Connection which provides and ultra secure fit that allows the user to pick up and deliver the screw using only one tool, reduces driver slippage and provides excellent driving torque upon delivery.
  • All short screws (3mm, 4mm and 5mm) are designed to secure titanium mesh and membranes. There is no need to use an additional tool or a mallet to deliver.

6mm: 4mm Threaded (Pack of 5) 6mm: 4mm Threaded / 2mm Unthreaded (Pack of 5)

  • All medium length screws (6mm, 8mm, 10mm, 12mm and 14mm) are partially threaded and tapered. These screws are designed to secure bone blocks and as adjustable tenting screws. For bone blocks, the partially unthreaded portion functions as a lag screw and provides intimate contact of the bone to the host. Use a 2.0mm drill to drill through the bone block. Blocks secured by fully threaded screws cannot achieve this level of host adaptability without the thread binding to the block and pulling away from the host.
  • The tapered design on the medium length screws also functions as an Adjustable Tenting Screw allowing the clinician to adjust the height/direction from 1-2mm when used in tenting procedures. Competitor tenting screws have a flat shelf in-between the threaded and unthreaded portions which locks in the height of the tenting portion of the screw. Our tapered design allows the clinician to adjust the height of the “tent-pole” to suit the clinical application.

8mm: 5mm Threaded (Pack of 5) 8mm: 5mm Threaded / 3mm Unthreaded (Pack of 5)

  • All medium length screws (6mm, 8mm, 10mm, 12mm and 14mm) are partially threaded and tapered. These screws are designed to secure bone blocks and as adjustable tenting screws. For bone blocks, the partially unthreaded portion functions as a lag screw and provides intimate contact of the bone to the host. Use a 2.0mm drill to drill through the bone block. Blocks secured by fully threaded screws cannot achieve this level of host adaptability without the thread binding to the block and pulling away from the host.
  • The tapered design on the medium length screws also functions as an Adjustable Tenting Screw allowing the clinician to adjust the height/direction from 1-2mm when used in tenting procedures. Competitor tenting screws have a flat shelf in-between the threaded and unthreaded portions which locks in the height of the tenting portion of the screw. Our tapered design allows the clinician to adjust the height of the “tent-pole” to suit the clinical application.

10mm: 5mm Threaded (Pack of 5) 10mm: 5mm Threaded / 5mm Unthreaded (Pack of 5)

  • All medium length screws (6mm, 8mm, 10mm, 12mm and 14mm) are partially threaded and tapered. These screws are designed to secure bone blocks and as adjustable tenting screws. For bone blocks, the partially unthreaded portion functions as a lag screw and provides intimate contact of the bone to the host. Use a 2.0mm drill to drill through the bone block. Blocks secured by fully threaded screws cannot achieve this level of host adaptability without the thread binding to the block and pulling away from the host.
  • The tapered design on the medium length screws also functions as an Adjustable Tenting Screw allowing the clinician to adjust the height/direction from 1-2mm when used in tenting procedures. Competitor tenting screws have a flat shelf in-between the threaded and unthreaded portions which locks in the height of the tenting portion of the screw. Our tapered design allows the clinician to adjust the height of the “tent-pole” to suit the clinical application.

12mm: 6mm Threaded (Pack of 5) 12mm: 6mm Threaded / 6mm Unthreaded (Pack of 5)

  • All medium length screws (6mm, 8mm, 10mm, 12mm and 14mm) are partially threaded and tapered. These screws are designed to secure bone blocks and as adjustable tenting screws. For bone blocks, the partially unthreaded portion functions as a lag screw and provides intimate contact of the bone to the host. Use a 2.0mm drill to drill through the bone block. Blocks secured by fully threaded screws cannot achieve this level of host adaptability without the thread binding to the block and pulling away from the host.
  • The tapered design on the medium length screws also functions as an Adjustable Tenting Screw allowing the clinician to adjust the height/direction from 1-2mm when used in tenting procedures. Competitor tenting screws have a flat shelf in-between the threaded and unthreaded portions which locks in the height of the tenting portion of the screw. Our tapered design allows the clinician to adjust the height of the “tent-pole” to suit the clinical application.
  • Additional longer fully threaded screws are available in lengths of 15mm, 18mm, 21mm and 24mm for Vertical Vascular Osteotomy Procedures.

14mm: 7mm Threaded (Pack of 5) 14mm: 7mm Threaded / 7mm Unthreaded (Pack of 5)

  • All medium length screws (6mm, 8mm, 10mm, 12mm and 14mm) are partially threaded and tapered. These screws are designed to secure bone blocks and as adjustable tenting screws. For bone blocks, the partially unthreaded portion functions as a lag screw and provides intimate contact of the bone to the host. Use a 2.0mm drill to drill through the bone block. Blocks secured by fully threaded screws cannot achieve this level of host adaptability without the thread binding to the block and pulling away from the host.
  • The tapered design on the medium length screws also functions as an Adjustable Tenting Screw allowing the clinician to adjust the height/direction from 1-2mm when used in tenting procedures. Competitor tenting screws have a flat shelf in-between the threaded and unthreaded portions which locks in the height of the tenting portion of the screw. Our tapered design allows the clinician to adjust the height of the “tent-pole” to suit the clinical application.
  • Additional longer fully threaded screws are available in lengths of 15mm, 18mm, 21mm and 24mm for Vertical Vascular Osteotomy Procedures.